Specifications
| Power Total Rated | 3700.00 |
| Pumping Speed Air Nitrogen (@50Hz or max @default setting) | 0.028 0.028 |
| Pressure Ultimate | 1.00 |
LEYVAC LV 120 B, 410, 200V
Part Number: 19200120V31CQV
Variant
Explore the range of variants given below to compare the product
| Short Description | Part Number |
|---|---|
| 19200120V30CQV | |
| 19200120V31CQV |
General Product Information
| Dimension Height | 0.587 |
| Dimension Length | 0.813 |
| Dimension Width | 0.379 |
| Leak Rate | 1.000 × 10⁻⁶ |
| Noise / Sound Level |
65.00
db(A)
65.00 db(A) |
| Weight | 235.00 |
| Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
| Connection Inlet / Outlet Flange | DN 63 ISO-K | DN 40 ISO-KF (NW40) |
| Certification of Product |
CE
RoHS |
Performance Data
| Capacity Water Vapour |
1.630 × 10⁻⁴
1.630 × 10⁻⁴ |
| Power at Ultimate | 1700.00 |
| Power Total Rated | 3700.00 |
| Power Total Rated @50Hz | 3700.00 |
| Power Total Rated @60Hz | 3700.00 |
| Pressure Ultimate | 1.00 |
| Pumping Speed Air Nitrogen (@50Hz or max @default setting) |
0.028
0.028 |
Environmental Conditions
| Temperature Ambient Operation Max | 45.00 |
| Temperature Ambient Storage Max | 60.00 |
| Temperature Ambient Operation Min | 5.00 |
| Temperature Ambient Storage Min | -10.00 |
Classification
| Classification Dry or Wet Pump | Dry |