Specifications

Connection Inlet Flange DN 160 ISO-K
Connection Outlet Flange DN 160 ISO-K
Cooling Method Air Cooling
Power Supply Voltage 3Ph 200/230/400V 50 Hz 3Ph 200-208/265/460 60 Hz
Power Total Rated 7500.00
Pumping Speed Air Nitrogen 0.514

RUVAC WSU 2001 H - PFPE 100Hz

Part Number: 155066

Contact us for availability

Click For Availability

General Product Information

Connection Outlet Flange DN 160 ISO-K
Connection Inlet Flange DN 160 ISO-K
Cooling Method Air Cooling
Dimension Height 0.530
Dimension Length 1.04
Dimension Width 0.642
IP Rating IP20
Leak Rate 1.000 × 10⁻⁵
Noise / Sound Level 72.00 db(A)
Power Supply Frequency 50 Hz
60 Hz
Power Supply Phase 3-Ph
Power Supply Voltage 3Ph 200/230/400V 50 Hz
3Ph 200-208/265/460 60 Hz
Weight 465.00
Dimension Comments The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models.
Connection Inlet / Outlet Flange DN 160 ISO-K | DN 160 ISO-K

Performance Data

Nominal Capacity 60Hz 0.683
Nominal Capacity 50Hz 0.569
Power Total Rated 7500.00
Power Total Rated @50Hz 7500.00
Power Total Rated @60Hz 8500.00
Pumping Speed Air Nitrogen 0.514
Pumping Speed Air Nitrogen 50Hz 0.583
Pumping Speed Air Nitrogen 60Hz 0.514

Environmental Conditions

Temperature Ambient Operation Max 40.00
Temperature Ambient Operation Min 12.00

Classification

Classification Dry or Wet Pump Dry
Classification Product Pressure Range Medium Vacuum: 1 mbar - 1·10⁻³ mbar
Rough Vacuum: 1000 mbar - 1 mbar
Classification High / Medium / Rough Vacuum pump Rough Vacuum Pump
Classification Vacuum Pump Technology Mechanical Booster Pump
Product Title Part Number Add to cart